R46 IS REPLACED BY
22 GA JUMPER WIRE FOR
-004, -005 & -006 ASSY.
FOR -001, -002, -004 &
-005 : 430 OHM
FOR -003, & -006 : 2KOHM.
JW13 EACH END TO P4 AND P5 ON
POT-SUB BOARD FOR 230V VERSIONS
(-002 & -005) ONLY.
THIS PORTION OF CIRCUIT FOR 120V (-001 & -004)
AND 100V (-003 & -006) VERSION AMPS ONLY.
SEE FIG. 2 FOR -002 & -005 (230V) VERSION AMPS.
THIS PORTION OF CIRCUIT FOR 120V (-001 & -004) AND 100V
(-003 & 006) VERSION AMPS ONLY.
SEE FIG. 1 FOR -002 & -005 (230V) VERSION AMPS.
BI-COLOR LED USED ON 230V VERSION (-002 & -005).
RED =MUTEGREEN =UNMUTE
CR8 IS REPLACED BY 22GA JUMPER ON 230V VERSION (-002 & -005).
120V DOMESTIC VERSIONS (-002 & -005):USE 3AMP SLO-BLO FUSE
230V EUROPEAN VERSION (-002 & -005):USE 1.6 AMP 20mm SLO-BLO FUSE
100V ASIA VERSION (-003 & -006):USE 3.15 AMP 20mm SLO-BLO FUSE.
RESISTORS ARE 1/8W, 5% TOLERANCE UNLESS OTHERWISE SPECIFIED |